Product |
Size |
Viscosity |
Molecular Weight |
Composition |
Classification |
Healon D® OVD |
0.65mL |
40,000 mPas |
645,000 daltons |
3.0% NaHA |
Dispersive |
Healon GV® OVD |
0.55mL |
3,000,000 mPas |
5,000,000 daltons |
1.4% NaHA |
Cohesive |
"Healon® D+GV gives me the best of both worlds. Healon D® protects the corneal endothelium throughout the procedure and Healon GV® provides space maintenance and control."
- Uday Devgan, MD
Los Angeles, California
Clear — Healon D® OVD
- Complete clarity in surgical field
- Highly protective of endothelial cells1
Control — Healon GV® OVD
- Exceptional control and ease of removal
- Highest molecular weight cohesive available in OVDs2
Healon® D+GV Ophthalmic Viscosurgical System combines a clear dispersive with the highest molecular weight cohesive for the first time in a combination pack. By bringing together these premium OVDs, Healon® OVDs offer the space maintenance, control, endothelial cell protection, and flexibility you need to improve patient outcomes during cataract surgery.
Healon D® OVD protects corneal endothelial cells, while Healon GV® OVD deepens the anterior chamber and flattens the anterior capsule.
Healon D® Dispersive OVD delivers clear protection
- Provides exceptional clarity in the surgical field
- Low molecular weight assures outstanding retention
- Provides optimum protection of endothelial cells throughout the entire surgical process1
- Ideal for lubrication of IOL insertion systems
Healon GV® Cohesive OVD provides exceptional Control
- High viscosity for increased anterior chamber expansion and maintenance
- Highest molecular weight of any ophthalmic viscosurgical devise on the market2
- Expands anterior chamber and flattens anterior capsule to facilitate capsulorhexis
- Long molecular chain designed to facilitate removal
References
- Viscoelastic materials and corneal endothelium. In: Buratto L, Giardini P, Bellucci R, eds. Viscoelastics in Opthalmic Surgery. Thorofare, NJ: Slack Inc; 2000:49-55
- Hütz WW, Eckhardt B, Kohnen T. Comparison of viscoelastic substances used in phacoemulsifi cation. J Cataract Refract Surg. 1996;22:955-959.
Intended use statement
Healon GV® and Healon D® OVDs are used in ophthalmic surgical procedures to maintain a deep anterior chamber that facilitates manipulation inside the eye with reduced trauma to the corneal endothelium and other ocular tissues.
Warnings/Precautions/Contraindications: There are no known contraindications to the use of Healon GV® and Healon D® OVDs when used as recommended. Please refer to package inserts for full prescribing information. Rx only.